VME bus principle, characteristics, functional structure and development analysis

Jun 26, 2025 Leave a message

VME bus principle and application


VME (VersaModule Eurocard) bus is a general-purpose computer bus that combines the electrical standard of Motorola's Versa bus with the mechanical form factor of the Eurocard standard established in Europe, and is an open architecture. It defines a system for interconnecting data processing, data storage and connecting peripheral control devices in a closely coupled hardware architecture. Over the years, the VME system has evolved into a well-established system around which products have been developed for industrial control, military systems, aerospace, transportation and medical applications.


Features of VME


VME's data transfer mechanism is asynchronous, with multiple bus cycles, address widths of 16, 24, 32, 40 or 64 bits, and data line widths of 8, 16, 24, 32, and 64 bits, and the system can select them dynamically. Its data transfer method is asynchronous, so it is only subject to the signal exchange protocol and does not depend on the system clock; its data transfer rate is from 0 to 500 Mb/s; in addition, there is Unaligned Data transfer capability, error correction and self-diagnostics, and user-defined I/O ports; it is equipped with 21 plug-in slots and multiple backplanes, which can be used in military applications Conduction Cooling Module.


VME Architecture


Because it is a combination of two standards, the VME system can also be viewed as two parts. One part is the mechanical architecture, which determines the size of the backplanes, front panels and embedded boards of the VMEbus system, and the other part is the functional architecture, which defines the system's flow.


1. VME Mechanical Architecture


The main part of the VME mechanical structure is the backplane, which is a printed circuit board. It is available in three sizes: 3U (160 mm × 100 mm), 6U (160 mm × 233 mm), and 9U (367 mm × 400 mm). According to the VME64x standard, there are three types of connectors in the VME system, which are P0/J0, P1/J1, and P2/J2, with "P" and "J" standing for PLUG and JACK connectors respectively. The P1/J1 and P2/J2 connectors have 96 pins arranged in three rows of 32 pins each, while the P0/J0 connector has 95 pins. 3U backplanes only have P1/J1 or P2/J2 connectors, while 6U backplanes have both J1 and J2 connectors.

 

2. Functional structure of VME

As shown in Figure 1, the functional architecture of the VME can be described as consisting of signal lines, backplane interface logic and functional modules. The performance of the backplane interface logic is governed by a number of characteristics on the backplane, such as signal line impedance, propagation time, termination values, and so on. It and the signal lines are the link between the various parts of the system. Functional modules, on the other hand, are collections of circuits that perform specific tasks. Among them, the main module is called the master, which determines the order of data transmission; the modules that act according to the data transmission of the master are called slaves, and the module responsible for monitoring the address of the data transmission destination is called the location monitoring device. In addition, there are modules that issue and process interrupt requests, and arbitration modules that determine and process requests from other modules. Of course, there are also modules that issue clock signals and modules that monitor the operation of the system's power supply.

VME总线原理,特点,功能结构及发展分析                VME Functional Architecture

 

Each of these modules has its own division of labor, but to work together collectively, they need the support of buses.The buses of the VME system are divided into four major categories: the data transfer bus, the data transfer arbitration bus, the priority interrupt bus, and the general-purpose bus.


The data transfer bus is a high-speed asynchronous parallel data transfer bus capable of transferring data and address signals. Master devices, slave devices, interrupt modules and interrupt handling modules exchange data two by two via it. Two other modules, the bus timer and the JACK daisy-chain driver, also participate in data processing via the data transfer bus.


The data transfer arbitration bus is set up to ensure that only one module occupies the data transfer bus at a given time. The request and arbitration modules working on it will load coordinate the commands issued by the modules. The arbitration module is in the first slot of the backplane and determines which master device will have priority in using the bus resources. Specific determination methods include a priority algorithm, a round-robin algorithm, and other sequencing algorithms. The priority interrupt bus is the bus that handles interrupt requests for each module. Various interrupt requests are categorized into seven levels in the VME, and depending on the level of the level, they work in order to interrupt the signal lines.


The last bus is the general purpose bus. The so-called general-purpose bus is the bus that is responsible for some of the basic tasks of the system, including control of the clock, initialization, error detection, and other tasks. It consists of two clock lines, a system reset line, a system failure line, an AC failure line, and a serial data line.


The modules are distributed in a parallel structure, and all data and commands are transmitted through the underlying Class 4 bus of the system, and the mode of the signals is TTL level signaling.

 

VME bus family


● VME64


With the development of peripheral technologies, upgrading of the VME system was inevitable. In 1995, VME64, a new generation of VME bus architecture, was launched. Compared with the traditional VME system, VME64 increases the transmission bandwidth, expands the address space, and facilitates board plugging and unplugging. It extended the data line width and address range to 64 bits for 6U boards, provided 32-bit and 40-bit address modules for 3U boards, increased the transmission bandwidth to 80Mb/s, increased the bus lock cycle, added the first slot detection function, and added support for hot-plugging.


● VME64 extension


The VME64 extension is a new standard adopted in 1997 and is also known as VME64x. It adds a 160-pin connector family (arranged in 5 rows), a P0/J0 connector between P1/J1 and P2/J2, and a new 3.3V power pin. The system's two new edge bus loops increase the data rate to 160 Mb/s. In addition, an EMC front panel and ESD features have been added.


● VME320


Perhaps the biggest improvement in the VME320 is the use of a star interconnect for the purpose of data transfer acceleration. It uses a protocol called 2eSST, which is a source synchronous transfer protocol that increases the theoretical data rate to 320 Mb/s. The VME320 is not widely supported, however.


There are many other protocols derived from VME that are not described here.


Trends in VME


The current advantage of VME technology lies in its many years of technical accumulation, its complete specification and strong technical support to meet the specific requirements of most customers. In addition, its modularity is also a very big advantage, because for many embedded systems, adding additional I/O is a common thing, and VME can very well meet this feature. VME provides 21 expansion slots, and the newly added modules do not affect the overall performance of the system.


However, VME is a technology that was born 25 years ago, and many users are not satisfied with the progress of VME in terms of bandwidth. Because in this era of massive data, bandwidth is an overwhelming indicator. However, vendors have not lost faith in VME, and are doing everything they can to extend the life of VME. the VXS standard introduced by SBS and the VPX standard developed by VITA (the VME International Trade Association) is a new attempt. vXS creates the conditions for references to switched fabrics, while VPX raises the switched fabric signal rate to 6.25 Gb/s. At the same time, many VME bus backplanes are beginning to be used in the same manner. Many VMEbus backplanes began using PMC (PCI Mezzanine Card) slots to enable direct use of PCI boards. Manufacturers also took the constructional elements of PCI cards to keep VME boards up to date with the industry.


VME's achievements are well recognized, but manufacturers will have to continue to work hard to rejuvenate it over the next decade. A quiet decline for this very resilient technology is probably not something most people would like to see.