I. INTRODUCTION
As an important device in the field of modern industrial control, frequency converter is widely used in motor speed control. However, in practical applications, sometimes encountered frequency converter drive motor running jitter problem. This jitter not only affects the normal operation of the motor, but also may have an adverse effect on productivity and equipment life. Therefore, an in-depth understanding of the causes of shivering when the inverter-driven motor is running, and take corresponding treatment methods, to ensure stable and efficient operation of the motor is of great significance.
II. Frequency converter driven motor shivering causes
The causes of shivering when the motor is running driven by frequency converter may involve many aspects, mainly including the following aspects:
Power supply problem
Unstable power supply voltage or poor power line quality is one of the common causes of shivering when the motor is running. When the power supply voltage fluctuates greatly, the inverter may not be able to stabilize the output voltage at the desired frequency, which leads to unstable motor speed and shivering.
Motor Problems
Problems with the motor itself, such as imbalance or uneven magnetic field, may also lead to jitter during operation. For example, motor rotor imbalance, bearing wear, loose parts inside the motor, etc. may trigger the jitter phenomenon.
Parameter setting problems
Irrational parameter settings of the frequency converter may also lead to motor jitter during operation. For example, improper parameter settings such as acceleration time, deceleration time, maximum frequency, etc. may affect the output performance of the frequency converter, resulting in unstable motor speed.
Control Logic Problems
Problems in the control logic of the frequency converter, such as irrational adjustment of the speed control link, may also lead to jitter when the motor is running. In addition, if the inverter fails to fully consider the characteristics and changes of the load when controlling the motor, it may also lead to motor jitter.
Load problem
Load instability affects the stability of motor operation, resulting in jitter. For example, load fluctuations, load inertia, etc. may have an effect on motor operation.
Fault problem
Faults in the inverter or the motor itself, such as wear and tear of the motor bearings, inverter circuit faults, etc., may also lead to jitter during operation.
III. Methods to deal with shivering when running with inverter-driven motor
For the problem of shivering generated when the motor is running driven by the inverter, the following methods can be taken to deal with it:
Check the power supply
First of all, the power supply voltage and frequency should be checked to see if it is stable, and whether the quality of the power supply line is good. If there is a problem with the power supply, corresponding measures need to be taken, such as replacing the power supply and increasing the voltage regulator, etc., to ensure that the power supply voltage and frequency are stable.
Regularly check the motor
Regularly check the operating status of the motor to find and repair motor problems. For example, balance the motor rotor, repair problems such as uneven magnetic field, etc. to ensure the normal operation of the internal parts of the motor.
Reasonable setting of parameters
Reasonably set the parameters of the inverter according to the characteristics of the motor and working requirements. For example, adjust the acceleration time and deceleration time according to the load characteristics, and adjust the maximum frequency according to the working requirements. By reasonably setting the parameters, the output performance of the inverter can be improved and the motor jitter can be reduced.
Optimize the control logic
Check the control logic of the inverter and optimize the parameter settings of the speed regulation link. For example, adjust the proportional gain and integration time of the speed regulation link according to the actual needs to improve the stability and accuracy of control. In addition, the characteristics and changes of the load should be fully considered to ensure that the frequency converter can stably control the motor operation.
Add stabilizing device
According to the needs, increase the deceleration device, install stabilizers, etc., to improve the stability of the load. By installing stabilizers, the impact of load fluctuations on motor operation can be reduced, reducing the possibility of motor jitter.
Regular inspection of equipment
Regularly check the operating status of equipment to detect and repair faults. For example, replace motor bearings and repair inverter circuits. By regularly checking the equipment, problems can be found and solved in time to ensure the normal operation of the equipment.
Setting the jump frequency
When the motor resonates, the resonance point can be avoided by setting the jump frequency of the inverter. For example, a certain frequency range is set as the jump frequency, and the inverter does not output frequency within the range, thus avoiding the motor running at the resonance point.
Dealing with power supply high harmonics
High harmonics in the power supply may cause unstable motor operation. Installing reactors in the power supply system can filter out high harmonics, improve power quality and reduce the impact of harmonics on motor operation.
Decentralize power and signal lines
In order to reduce the noise generated by the frequency converter on the motor operation of the interference, you can take measures to decentralize the power line and signal line. The use of shielded wires can reduce electromagnetic interference and improve the stability of signal transmission.
Installation of surge suppressors and data line filters
Installing surge suppressors and data line filters where needed can further reduce the effects of electromagnetic interference and noise and improve the stability of motor operation.
IV. Conclusion
Shivering when the inverter-driven motor is running is a complex problem that involves a number of factors. Through in-depth analysis of the causes of shivering and the adoption of corresponding processing methods, the problem of motor shivering can be effectively solved to improve the operating efficiency and stability of the motor. In practical application, appropriate treatment methods should be selected according to the specific situation, and regular inspection and maintenance of the equipment should be carried out to ensure the normal operation and prolong the service life of the equipment.