Mitsubishi inverter as an important device in the field of industrial control, its output input frequency setting for the normal operation of the equipment and efficiency enhancement has a vital role. This article will introduce in detail how to set the output input frequency of Mitsubishi inverter, and around this topic to develop a detailed discussion to ensure that readers can fully understand and master the relevant operations.
First, the output frequency setting
Understanding the basic parameters of the inverter
Before setting the output frequency, you first need to understand the basic parameters of the Mitsubishi inverter, including the main frequency, starting frequency, acceleration time and deceleration time. The setting of these parameters will directly affect the output frequency and performance of the inverter.
Main frequency setting: the main frequency is the maximum value that the output voltage and frequency of the Mitsubishi inverter can reach. According to the actual need, it is generally recommended to be set to 1.5 times the rated voltage of the working motor. For example, when the rated voltage of the working motor is 380V, the main frequency can be set to 570Hz.
Starting frequency setting: the starting frequency is the initial point where the output voltage and frequency of the inverter gradually increase from zero. It is generally recommended that the starting frequency be set at about 20% of the main frequency.
Acceleration time and deceleration time setting: the acceleration time is the time required for the inverter to gradually increase the output voltage and frequency from the starting frequency to the main frequency, and the deceleration time is the time required for the output voltage and frequency to gradually decrease from the main frequency to the starting frequency. It is generally recommended to set it between 2 and 5 seconds.
Steps for setting the output frequency
Setting the output frequency of Mitsubishi inverter needs to be done according to the following steps:
Open the panel of the inverter controller: first, you need to open the panel of the inverter controller and enter the frequency setting menu. Find the menu of "Frequency Setting" or "Speed Setting" on the control panel or touch panel.
Select the output frequency: In the frequency setting menu, select the "output frequency" option. At this point, you can use the up or down arrow keys to change the output frequency.
Enter Frequency Value: Enter the desired frequency value as needed. This value is usually in Hertz (Hz) and can be selected according to the equipment requirements.
Confirm and save the setting: After inputting the frequency value, you need to confirm the setting is correct. Then press the "Enter" key or the corresponding save button to save and exit the settings.
Cautions
When setting the output frequency, you need to pay attention to the following points:
The rated input voltage and rated frequency range of the frequency converter should be known before adjustment to avoid inputting wrong parameters leading to equipment failure or danger.
According to the actual working environment and motor load, set the parameters such as main frequency, starting frequency, acceleration time and deceleration time reasonably to ensure the normal operation and performance optimization of the equipment.
Second, the input frequency setting
For the input frequency setting of Mitsubishi inverter, it mainly involves the control mode of analog input. When it is necessary to control the output frequency of the inverter through analog signals (such as 0-20mA or 0-5V), the following settings are required:
Setting the DIP switch
According to the requirements of the on-site equipment, set the dip switches on the Mitsubishi inverter accordingly. For example, set dip switch 1 to OFF (terminal 2 voltage mode) and switch 2 to ON (terminal 4 current mode).
Setting Parameters
Enter the parameter setting interface of the inverter and set the relevant parameters. For example, set parameter Pr73 to 1 (terminal 2 is 0-5V input) and parameter Pr267 to 0 (terminal 4 input range 4-20mA). At the same time, set the corresponding gain frequency parameters (e.g. Pr125 and Pr126) according to the requirements of the field equipment.
Wiring and Setting
According to the set parameters and wiring requirements, carry out the actual wiring operation. After ensuring that the wiring is correct, carry out relevant tests and adjustments to ensure that the input frequency control function of the frequency converter is normal.
Third, the summary
This paper describes in detail how to set the output input frequency of Mitsubishi inverter. By setting the main frequency, start frequency, acceleration time and deceleration time and other parameters as well as the control mode of analog input, the precise control of the output frequency of the inverter can be realized. At the same time, attention needs to be paid to relevant matters and details in the actual operation process to ensure the normal operation and performance optimization of the equipment. I hope this article can help and inspire the majority of Mitsubishi inverter users.