What is an overcurrent fault

Apr 29, 2024 Leave a message

What happens when a VFD fails and you see it shut down due to an overpressure condition? At that point, a good understanding of what caused this to happen would be valuable information as your goal is to get the VFD back online.

 

An overvoltage fault occurs in the core when the voltage measured at the drive DC bus is higher than a predetermined overvoltage trip point. When this occurs, VFD protection kicks in and will take it offline due to the fault.

 

This is most commonly indicated by a fault screen display such as "oV" or "F05" depending on the make of the drive. This may occur when we delve into overvoltage faults:

 

Load Deceleration

 

  • When a motor begins to decelerate (think of applying the brakes in your car), it sends power back to the drive, where it is dissipated by the drive's braking circuits or by an active front end in a regenerative application.
  • When the braking time is too short and the load has too much inertia, a larger energy spike is returned to the drive, causing the voltage on the bus to rise, resulting in an overvoltage spike.
  • Once you have determined that this is the likely culprit, one area to consider adjusting is the deceleration time. By increasing the deceleration time, you are actually spreading out the energy dissipation and giving the VFD more time to absorb the increase in regenerative voltage.
  • If this is not an option, you can look into ways to reduce the load on the motor. This will affect the regenerative voltage because when the load is reduced, the energy required to stop the load is also reduced.
  • If any of these options are not available, you can add braking resistors to the drive that will help absorb these voltages and prevent the VFD from being damaged by regenerative voltages.

 

Input Power Peaks

 

  • The power source that feeds your VFD will have an impact on your VFD and you need to know what to look for. This is primarily a function of the utility that powers your facility, or it could be coming from another source within your facility.
  • When you determine that this is the cause of the failure, it's time to take action. By adding an input reactor to the line side of your VFD, you can help protect your equipment from these surges.
  • The best way to avoid this is to monitor the input power from the utility. This will be a clear indicator if the problem is caused by the utility itself, or by another source within the facility. 

 

Rapid Load Changes

 

  • Often, when people troubleshoot VFDs, they spend all their time on the drive itself and not enough time evaluating the load. Load has a huge impact on how a VFD operates, and if it changes quickly, power spikes can occur on the system. This can be caused by something being added or removed from the system that the VFD is trying to compensate for.
  • In this case, the motor may experience excessive slippage as the motor tries to catch up with the synchronous speed. During this state, the system consumes more power.
  • To correct these problems, make sure the mechanical linkage around the motor is not binding point or slipping.
  • This is a good way to double check and make sure the VFD is rated for the application. 

 

Grounding Issues

 

  • Having a solid grounding system for many electrical devices is critical for longevity and reliability.
  • If a floating ground is present or if the ground was not properly installed from the beginning, you may begin to experience overvoltage faults.
  • If the ground is not installed correctly, it may energize and not remove unwanted dissipated voltage, resulting in an overvoltage condition.
  • To make sure this is not a problem, take the time to verify the grounding circuit with a quick test with a voltmeter. Voltage should not be present in a properly installed ground circuit, and if this is not the case, you will find the culprit that needs to be corrected. 