Increases reliability, improves safety and reduces operating costs of motor systems. Minimize commissioning and maintenance time. Standardize real-time motor and operating data for integration into the control system for process optimization. Access and integrate all available operating and diagnostic data for immediate and future use.
Achieving these goals is based on the core functionality of the Smart Motor Relay, which includes direct measurement of motor voltage, current and temperature, control of motor starter operation, easy configuration of fault and warning parameters, and standardized communication options for integration into the plant control system.
A typical Smart Motor Relay consists of a measurement module, control module, I/O module, user interface and communication module. Form-factor options for these components allow installation in existing motor control centers and stand-alone motor control cabinets as well as new replacement motor control systems.
Consider the following criteria when evaluating smart motor relays:
Pre-Fault Warning. User definable thresholds independent of actual fault thresholds to provide earlier indication of a fault. User selectable programmable delay. Fault (Trip) Function. User-defined fault thresholds with programmable delays at the parameter level. Programmable override or disable function, independently selectable for application-specific problems. Local Fault Capture. In the event of a fault condition, the unit will capture a set of diagnostic parameters (time-stamped) and store them in non-volatile memory (see below for details).
Start Cycle and Transition Timing. The device shall recognize motor stop, motor start, and motor transition modes of operation to align the start and run protection/operation profiles. Overload Protection. Is a function of NEMA trip level selection and motor design thermal capacity. The device shall allow programmable selection of standard trip levels and thermal modeling of protected motor conditions in non-volatile memory. Setpoint Security. Programmable security restricts those who can change setpoints and adequately protects the setpoint standard. Thermistor/RTD Input. A method of monitoring winding and bearing temperatures via a sensing device that provides fault and display capability.
Local Display. Accessory options shall include appropriate HMI displays that can be mounted locally to the unit (panel or MCC Door) to assist technicians in troubleshooting. Common communication protocol options; EtherNet I/P, Profinet, Modbus TCP, etc. Device operating status. If device components including power supplies, microprocessors, memory, analog-to-digital converters, or other related functions fail. Debugging. Predefined device data mappings, and sample configuration packages suitable for reuse.
This includes tag aliases and device register pre-mappings. A device interface accessible through a standard web browser will be provided to simplify debugging and create reusable templates.
A device is installed; non-volatile memory modules are provided for parameter backup. If a device fails, a new device can be commissioned in the field by transferring the memory module.
The factory default IP addressing scheme should be used so that technicians can set up IP addressing without any interface or programming requirements. One such available option allows the last octet of the IP address to be set using the device DIP switches.
Intelligent motor relays can be an integral part of your smart manufacturing journey, truly taking your factory to the next level in Industry 4.0.